Pipe
Relining Using Stainless Steel Links
Before
After


INSTA-LINER™:
LINK-PIPE INSTA-LINER™ forms a composite structure with the
damaged, or eroded host pipe and creates a new pipe even
where the old pipe is missing. The new composite pipe
combines the strength of the new liner with sections and
pieces of the host pipe, all bonded together with a
cementitious grout.
LINK-PIPE INSTA-LINER™ can be ordered with a 50-year,
100-year, or any custom designed service life.
In all cases, a 10-Year Manufacturer Limited Warranty
applies for all materials.
Application:
LINK-PIPE INSTA-LINER™ is made up of short links of
stainless steel sleeves, which are coupled together to
create a continuous liner of a specified length.
Individual links are coupled together and are pulled through
the host pipe by a cable from the opening at the far end of
the host pipe. A continuous stainless steel liner is thus
formed.
A specially formulated cement grout is then pumped to fill
the annular space between the host pipe and the
INSTA-LINER™. The grout flows into all cracks and joints,
joining together the INSTA-LINER™ and all old pipe sections
into a solid and unified structure.
The SST-316 INSTA-LINER™ is selected for the purpose of
providing a repair that lasts at least 100 years in a city
culvert, sanitary and storm sewer environment.
Deteriorated
CMPHost Pipe

LINK-PIPE
INSTA-LINER™ Links on job site

LINK-PIPE
INSTA-LINER™ Links insertion

LINK-PIPE INSTA-LINER™
Links insertion (con't)

LINK-PIPE INSTA-LINER™
Installation

LINK-PIPE INSTA-LINER™
showing relined Culvert

Benefits of LINK-PIPE
INSTA-LINER™ Method
|
- |
No excavation |
|
- |
No
traffic holdups |
|
-
|
No damage to Utilities
|
|
-
|
No
expensive installation equipment needed |
|
-
|
Only
one crew of three persons is needed to perform the
repair |
|
-
|
Repair Segment Installation requires very short
setup and installation time |
|
-
|
100-year long service
life |
|
- |
10-Year Limited Manufacturer Warranty |
Uses of
INSTA-LINER™
|
Structural
Repairs: |
|
|
Eroded
pipe requires relining |
|
|
longitudinal cracks |
|
|
circumferential cracks |
|
|
multiple cracks |
|
|
broken pipes |
|
|
holes |
|
|
laterals |
|
Reinstates |
|
|
partially collapsed pipes
|
|
|
totally collapsed or
missing pipe |
|
|
separated, misaligned and offset
joints |
|
Seals |
|
|
ex-filtrating of gravity flow pipes |
|
|
abandoned
services
|
DIMENSIONS:
|
Sleeve Diameter
|
Standard Gauge
|
|
6"
|
26
|
|
8"
|
24
|
|
10"
|
24
|
|
12"
|
24
|
|
15"
|
22
|
|
18"
|
20
|
|
21"
|
18
|
|
24"
|
18
|
|
27"
|
18
|
|
30"
|
16
|
|
33"
|
16
|
|
36"
|
16
|
|
42"
|
16
|
|
48"
|
14
|
|
54"
|
14
|
|
Standard
Lengths:
12", 18", 24" and 36" |
NOTE:
Customization is available on request.